ASTM C1012 PDF

As researchers using ASTM C for sulfate resistance test for concrete. The size of the cube is x x mm. But ASTM C gives guidelines for. Table 1 Criticism of ASTM Sulfate Durability Tests (ASTM C and ASTM C) .. 8. Table 2 Designation, Classification, and Chemical Oxide Analysis of. C (ASTM a) Type II cement (moderate sulfate resistance) or Type V . chosen based on the ASTM C (ASTM b) specifications are shown in.

Author: Tygoshakar Yozshunris
Country: Norway
Language: English (Spanish)
Genre: Love
Published (Last): 5 April 2006
Pages: 318
PDF File Size: 3.65 Mb
ePub File Size: 6.99 Mb
ISBN: 332-1-63586-432-1
Downloads: 96302
Price: Free* [*Free Regsitration Required]
Uploader: Daibei

If you need more info or have any questions, please note the Lab ID number and contact us at:. Test Method C is suitable for evaluating portland cements but not blended cements or blends of portland cement with pozzolans or slags. Sample Type portland cement, blended cements, and supplementary cementing materials blended with portland cement.

It is the responsibility of the c1021 of this standard to establish appro- priate safety and health practices and determine the applica- bility of regulatory limitations prior to use.

When tests are made that are expected to produce results that are close to an acceptance- rejection value, it is recommended that reagent grade chemi- cals be used. If you need more info or have any questions, please note the Lab ID number and contact us at: Order Form 2 Email complete form to contact listed below. Determine the pH of the solution before use; reject the solution if the pH range is outside 6.

  ANICETO EL VENCECANGUELOS PDF

ASTM C1012/C1012M – 18a

A number in parentheses indicates the year of last reapproval. Can extend time of testing for additional charge.

It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

Testing goes to 1 year. Method C is suitable for evaluating portland asmt but not blended cements or blends of portland cement with pozzolans or slags.

There was a problem providing the content you requested

Work Item s – proposed revisions of this standard. Referenced Documents purchase separately The documents listed below are referenced c012 the subject standard but are not provided as part of the standard.

For mortar bars 25 by 25 by mm volume mLthis is to mL of solution per mortar bar in the storage container.

BoxFarmington Hills, MI A superscript epsilon e indicates an editorial change since the last revision or reapproval. Last previous edition approved in as C — Further discussion of these and other technical issues is given in the Appendix. Print and complete the following order form.

Current edition approved Jan. Seal the container with a lid so that the sulfate solution cannot evaporate. Reagents and Materials 5. The values shown in parentheses are for information purposes only. Use a water-cement ratio by mass of 0.

Further discussion of these and other technical issues is given in the Appendix. Within the text, the inch-pound units are shown in brackets.

Link to Active This link will always route to the current Active version of the standard.

  2008 DODGE CALIBER OWNERS MANUAL PDF

Use This c112 provides a means of assessing the sulfate resistance of a mortar. Historical Version s – view previous versions of standard. Significance and Use 3.

Any anhydrous or hydrated sodium sulfate may be used if the water content adtm the salt is checked by loss on ignition and proper corrections made to account for the specified sulfate concen- tration. Originally approved in Unless otherwise directed the exposure solution contains moles of Na2SO4 per m3. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Instructions Supply 5 kg sample.

ASTM C Hydraulic-Cement Mortars Exposed to a Sulfate | CTLGroup

Support the bars so that no awtm or side of a bar rests against the container. Such chemicals shall conform to the specifica- tions of the Committee on Analytical Reagents for the American Chemical Society where such specifications are available. The length change of mortar bars immersed in sulfate solution is the indicator.

Combining values from the two systems may result in non-conformance with the standard. Time for Results Please contact a CTLGroup chemical services representative or Project Manager to discuss your individual project needs and testing response times.

Other sulfate concentrations or other sulfates such as Satm may be used to simulate the environmental exposure of interest. Enviado por Murilo flag Denunciar.